TROUBLESHOOTING (cont.)

Problem

Possible Cause

Troubleshooting Procedures

Remove power from the brewer.

Connect a voltmeter across one of

the tank heaters. Reapply power

to the brewer and refer to Testing

Individual Components. If the full

supply voltage is measured when

the tank heater is turned on, and

zero voltage is measured with the

triac off, then the triac is good. If

half the supply voltage is measured,

the triac is defective. If very low, or

zero voltage is measured, there could

be a defective triac or a defective

control board.

Perform the above procedure for

testing triacs. If the voltage mea-

sured is very low or zero, then

substitute a control board known to

be in good working order.

Remove power from the brewer.

Connect a voltmeter across one of

the tank heaters. Reapply power

to the brewer and refer to Testing

Individual Components. If the full

supply voltage is measured when

the tank heater is turned on, and

zero voltage is measured with the

triac off, then the triac is good. If

half the supply voltage is measured,

the triac is defective. If very low, or

zero voltage is measured, there could

be a defective triac or a defective

control board.

Inspect the tank assembly for ex-

cessive lime deposits. Delime as

required.

3. Triac

4. Electronic Control Board

1. Triac

2. Lime Buildup

CAUTION - Tank and tank compo-

nents should be delimed regularly

depending on local water condi-

tions. Excessive mineral buildup on

stainless steel surfaces can initiate

corrosive reactions resulting in seri-

ous leaks.

Water will not heat or display shows

HEATING TIME TOO LONG (cont.)

Spitting or unusual steaming from

sprayhead or air vent. (Water too

hot)

35879.1 071405