PROGRAMMING THE BREWER (cont.)

SERVICE TOOLS

This function allows the testing of individual com-

ponents and the ability to check switches for proper

function. This function also tests the Soft Heat server's

status on the brewer (in place or removed), and the

funnel sensor coil's frequency (diagnostic tool for

troubleshooting purposes only).

EXIT TO

NEXT FUNCTION

SCREEN

EXIT TO

NEXT FUNCTION

SCREEN

PRESS AND RELEASE

® SYMBOL

PRESS AND RELEASE

® SYMBOL

NEXT COMPONENT

TO BE TESTED

TEST OUTPUTS?

NO YES

TEST SWITCHES?

NO YES

BREW VALVE

ON NEXT OFF

125.0 KHZ. 4

4 125.0 KHZ.

NOTHING PRESSED

TEST FREQUENCY?

NO YES

SERVICE TOOLS?

NO YES

P2757

Testing individual components (outputs):

This will allow the operator to test the operation

of individual components and outputs of the brewer.

The components that can be individually tested are as

follows:

Brew Valve

Bypass Valve

Funnel Lock (Optional)

Refill Valve

Tank Heaters

Heater Contactor

Procedure to test components (outputs):

1. Place brew funnels into rails on the brewer.

2. Place a Soft Heat server beneath the brew fun-

nel.

3. Press and hold the upper right hidden switch until

the display reads UNITS. Release the switch, then

press and release switch until the display reads

SERVICE TOOLS.

4. Press YES to run tests on various components

and outputs within the brewer. Pressing NO will

exit this function and advance to the next function

screen.

5. The display should read TEST OUTPUTS.

6. Press and release YES. The display should read

BREW VALVE.

7. To test BREW VALVE, press ON. If the brew valve

is functional, water should run from the brewer.

8. Press OFF to end flow of water.

9. Press NEXT to advance to the next component to

be tested.

NOTE: To bypass testing any component, press NEXT

to advance to the next one, without testing the previ-

ous component.

10. To test BREW BYPASS, press ON. If the bypass

valve is functional, water should run from the brew

bypass.

11. Press OFF to end flow of water.

12. Press NEXT to advance to the next component to

be tested.

13. To test FUNNEL LOCK, press ON. If the funnel lock

is functional, the lock will come down to hold the

funnel in place.

35879.1 071405