Bunn W/SMART FUNNEL S/N SNG0033000 & UP User Manual

Page 34

Advertising
background image

Page 34

PROGRAMMING THE BREWER (cont.)

Procedure to adjust the flow rate setting:

1. Press and hold the upper right hidden switch until

the display reads UNITS. Release the switch, then

press and release switch until the display reads

BYPAS OZ/M. The number represents what the

brewer thinks is the flow rate of the bypass valve

in ounces per minute.

2. If the actual flow rate of the bypass valve is known,

but is different than the number on the display,

use the (-) and (+) to enter the correct flow rate

in ounces per minute.

Procedure to adjust the flow rate setting:

1. Press and hold the upper right hidden switch until

the display reads UNITS. Release the switch, then

press and release switch until the display reads

SPRAY OZ/M. The number represents what the

brewer thinks is the flow rate of the sprayhead

valve in ounces per minute.

2. If the actual flow rate of the sprayhead valve is

known, but is different than the number on the

display, use the (-) and (+) to enter the correct

flow rate in ounces per minute.

3. When finished, press and release DONE. This saves

the new setting and advances to the next function

screen, BYPASS OZ/M. Another alternative is to

press the ON/OFF switch located on the switch

panel to exit SPRAY OZ/M function and return to

the MAIN SCREEN.

BYPASS OZ/M

This function allows the operator to view or to enter

the actual flow rate coming out of the bypass nozzle.

This is NOT used to change the actual flow rate, but to

tell the internal controller how fast the water is flowing.

The unit of measure is ounces per minute.

SPRAY OZ/M (cont.)

3. When finished, press and release DONE. This saves

the new setting and advances to the next function

screen, CALIBRATE FLOW. Another alternative is

to press the ON/OFF switch located on the front

switch panel to exit the BYPASS OZ/M function

and return to the MAIN SCREEN.

CALIBRATE FLOW

This function allows the operator to enter the actual

flow rate of the sprayhead and the bypass by dispens-

ing both separately for one minute. The volumes are

then entered in ounces per minute. (Oz/M)

Procedures to calibrate the sprayhead flow rate:

1. Place a container, accurately graduated in ounces,

and with a minimum capacity of 60 ounces, beneath

the funnel on the brewer.

2. Press and hold the upper right hidden switch until

the display reads UNITS. Release the switch, then

press and release switch until the display reads

CALIBRATE FLOW.

3. Press and release YES to advance to the SPRAY-

HEAD CAL? function screen. (Pressing NO in the

CALIBRATE FLOW screen will advance to the next

function screen, BREW COUNTERS).

4. Press and release the YES pad. The display should

read CONTAINER READY? If the container is under

the funnel, press YES. The display should read

CALIBRATE SPRAY .. PRESS BREW TO START.

5. Press and release the BREW switch. The display

should read CALIBRATE SPRAY .. 60 SEC TO FIN-

ISH. The 60 second timer on the display will count

down to zero. When the counter reaches zero, the

display will change to ENTER OZ., along with a

number measured in ounces per minute.

6. Measure the amount of water in the container

and using the (-) or (+), adjust the amount on the

display to match the amount in the container. Then

press DONE.

7. The display should now read NEW SPRAY FLOW,

along with the correct flow rate of the sprayhead

in ounces per minute. After about 5 seconds,

the display will return to the CALIBRATE FLOW

screen.

8. To exit the CALIBRATE FLOW program, press NO

to advance to the next function screen, or press

the ON/OFF switch located on the front switch

panel to exit the CALIBRATE FLOW function and

return to the MAIN SCREEN.

P2721

SPRAY OZ/M: XXX

(-)

DONE

(+)

P2721

BYPAS OZ/M: XXX

(-)

DONE

(+)

35879.1 071405