PROGRAMMING THE BREWER (cont.)

BREW COUNTERS

This function allows the operator to track the num-

ber of brew cycles completed. There is one resettable

counter, and one life counter that is not resettable.

EXIT TO

NEXT FUNCTION

SCREEN

XXXX

NEXT RESET

XXXX
NEXT

BREW COUNTERS?

NO YES

Procedures to view/reset the brew counters:

1. Press and hold the upper right hidden switch until

the display reads UNITS. Release the switch, then

press and release switch until the display reads

BREW COUNTERS.

2. Pressing NO in this screen will advance to the next

function. Press YES to view the first brew counter.

This number represents the brew cycles initiated

since that counter was last reset.

3. To reset the resettable counter to zero press

and release RESET when viewing that particular

counter's screen.

P2448

Procedure to set funnel detect:

1. Press and hold the upper right hidden switch until

the display reads UNITS. Release the switch, then

press and release switch until the display reads

FUNNEL DETECT.

2. NO or YES should be flashing to indicate the cur-

rent setting.

3. Select YES to prevent brewing if a Smart Funnel is

not correctly situated in the rails. If this function is

activated and a brew cycle is attempted with the

funnel not properly situated, the display will read,

FUNNEL NOT IN PLACE, until one is in place.

4. Select NO to allow brewing without a Smart Fun-

nel in place. This is selected when brewing with a

funnel other than a Smart Funnel (a regular brew

funnel).

5. When finished, press and release DONE. This will

retain the changes, exit this function screen and

advance to the next. Another alternative is to press

the ON/OFF switch located on the front switch

panel to exit the FUNNEL DETECT and return to

the MAIN SCREEN.

7. Measure the amount of water in the container, and

using (-) or (+), adjust the amount on the display

to match the amount in the container. Then press

DONE.

8. The display should now read NEW BYPASS FLOW,

along with the correct flow rate of the bypass in

ounces per minute. After about 5 seconds, the dis-

play will return to the CALIBRATE FLOW screen.

9. To exit the CALIBRATE FLOW function, press and

release NO to advance to the next function screen,

or press the ON/OFF switch located on the front

switch panel to exit the CALIBRATE FLOW function

and return to the MAIN SCREEN.

CALIBRATE FLOW (cont.)

4. To advance to the other counter, press and release

NEXT. This will advance to total brews (non-reset-

table).

5. When finished, press NEXT until the display reads

BREW COUNTERS. Press and release NO to ad-

vance to the next function screen, or press the

ON/OFF switch located on the front switch panel

to exit the BREW COUNTERS function and return

to the MAIN SCREEN.

FUNNEL DETECT (optional)

This function allows the operator to prevent the

start of a brew cycle if a Smart Funnel is not positioned

correctly in the funnel rails.

P2721

FUNNEL DETECT ?

NO

DONE

YES

35879.1 071405