Bunn W/SMART FUNNEL S/N SNG0033000 & UP User Manual

Page 45

Advertising
background image

Page 45

Troubleshooting Procedure

TROUBLESHOOTING (cont.)
Problem

Possible Cause

Check the sensitivity setting. Refer

to the Refill function. If the left

three digit number is less than the

right number, the machine “thinks”

it is full and the refill valve should

be off. If the left number is larger

than the right, then the refill valve

will automatically be turned on to

fill the tank. The right number is

the threshold setting and can be

adjusted to compensate for extreme

water conditions: very pure, low

conductance water requires a higher

setting, while high mineral content,

high conductance water requires

a lower setting. Note that the left

number changes from a high value

when water is NOT touching the refill

probe to a low value when water IS

touching the probe. For best opera-

tion, the right number should be set

to a value midway between these low

and high numbers. Before changing

the setting, confirm that the refill

probe is free of scale buildup and

the connection to it is secure.

Test the Refill valve. Refer to Testing

Individual Components.

When this condition occurs, the

brewer will display OVERFLOW CUP

FULL. EMPTY CUP. The reason for

overfilling could be a defective refill

valve, an incorrect sensitivity setting,

(see above) or boiling.

Substitute a control board known to

be in good working order.

Foreign material lodged in valve,

holding it in open state.

3. Refill Probe or Sensitivity Set-

ting

4. Refill Valve

5. Overflow Protection Switch

6. Electronic Control Board

1. Refill valve

Automatic refill will not operate or

display shows FILL TIME TOO LONG

(cont.)

Water flows into tank continuously

with power removed from brewer.