Bunn W/SMART FUNNEL S/N SNG0033000 & UP User Manual

Page 38

Advertising
background image

Page 38

to TEST SWITCHES.

7. Pressing NO in this screen will advance to the

next function. Press YES in the TEST SWITCHES

screen to test the switches. The display will read

NOTHING PRESSED.

8. From this screen, press any of the switches on the

front of the brewer. While the switch is pressed,

the display shows the name of that switch. If the

name does not appear, or if it remains after the

switch has been released, the switch is defective.

Each switch can be tested in this manner.

9. After all switches have been tested, press the up-

per right hidden switch located on the front switch

panel. This will exit TEST SWITCHES and return

to the MAIN SCREEN.

Procedures to test coil frequency:

1. Place brew funnel into rails of the brewer.

2. Place a server beneath the brew funnel.

3. Press and hold the upper right hidden switch until

the display reads UNITS. Release the switch, then

press and release switch until the display reads

SERVICE TOOLS.

4. Pressing NO will exit this function and advance to

the next function screen. Press YES to run tests

on various components and outputs within the

brewer.

5. The display should read TEST OUTPUTS.

6. In TEST OUTPUTS screen, press NO. Continue to

press and release NO until the display reads TEST

FREQUENCY.

7. Press and release YES. The display will show the

frequency of the sensor coil circuits. This is for

diagnostic service use when troubleshooting this

circuit.

8. After the coils have been tested, press and release

the ON/OFF switch located on the front switch panel.

This will exit the TEST FREQUENCY function and

return to the MAIN SCREEN.

NOTE: If the operator wishes to test more than one

function in the SERVICE TOOLS section (outputs,

switches, servers, or coil frequency), it is not

necessary to exit the program. Use the flow chart

for SERVICE TOOLS to navigate to a particular

function.

SERVICE TOOLS (cont.)
14. Press OFF to retract the funnel lock.

15. Press NEXT to advance to the next component to

be tested.

16. To test REFILL VALVE, press ON. If the refill valve

is functional, the sound of the valve operating will

be heard.

17. Press OFF to end testing of refill valve.

18. Press NEXT to advance to the next component to

be tested.

19. To test TANK HEATER, connect a voltmeter across

the tank heater to check for voltage.

20. Press ON. The correct voltage should be present

at the heater terminals.

21. Press OFF to end testing of the tank heater.

NOTE: The tank heater will automatically turn off if

left on too long.

22. After testing the tank heater, press NEXT to advance

to the next test.

23. The HEATER CONTACTOR is used only on certain

models. Check the machine schematic to see if the

contactor is present. Connect a voltmeter across

the tank heater and press ON to check that cor-

rect voltage is present. Press OFF and confirm the

voltage is zero.

24. Press NEXT to return to TEST OUTPUTS.

25. To exit SERVICE TOOLS, press and release the

ON/OFF switch located on the front switch panel.

This will return to the MAIN SCREEN.

Procedure to test switches:

This function allows the operator to test the opera-

tion of the individual switches on the front panel.

1. Place brew funnel into rails on the brewer.

2. Place a server beneath the brew funnel.

3. Press and hold the upper right hidden switch until

the display reads UNITS. Release the switch, then

press and release switch until the display reads

SERVICE TOOLS.

4. Press YES to run tests on various components

and outputs within the brewer. (Pressing NO will

exit this function and advance to the next function

screen.)

5. The display should read TEST OUTPUTS.

6. In TEST OUTPUTS screen, press NO. This advances

PROGRAMMING THE BREWER (cont.)

35879.1 071405

Advertising