10-2860 B Series COP Instructions RevB 111117

EPM Harness

Connect the 4-pin connector on the EPM harness to the mating connector on the EPM.
Make sure the connector is fully seated and locked into position. Route the harness
through the engine bay, away from any high heat sources and sharp objects, towards
the ECU. See Figure 9 below.




Wiring

EPM Harness

RED – EPM Power, Connect to 12 volts


BLACK – EPM Ground, connect to ground


GREEN – Crank Signal, connect to crank input on EMS/ECU


WHITE – Cam Signal, connect to cam input in EMS/ECU


DRAIN WIRE – Connect to power ground/drain in EMS/ECU



Figure 9. EPM Harness Connected to EPM