18
© 2014 AEM Performance Electronics
P/N 30-3812
C2-43
LowsideSwitch_
8
Ford
Racing
PCM70 -
7
Starter Motor Control
(SMC)
Lowside switch, 4A max
with internal flyback
diode. Inductive load
should NOT have full time
power.
See Setup Wizard Page "LowSide
Assignment Tables" for configuration
options. See 2D table "LS8_Duty [%]"
for activation settings.
C2-44
LowsideSwitch_
7
Engine
E - 57
Variable Camshaft
Timing 22 Solenoid
(Driverside Exhaust)
Lowside switch, 4A max
with internal flyback
diode. Inductive load
should NOT have full time
power.
'See Setup Wizard Page "LowSide
Assignment Tables" for configuration
options. See 2D table "LS7_Duty [%]"
for activation settings. See Setup
Wizard page 'VVC' for options.
C2-45
UEGO 2 VM
Ford
Racing
PCM50 -
40
UEGO 2 VM
Bosch UEGO Controller
Virtual Ground signal. Connect to pin
5 of Bosch UEGO sensor.
C2-46
UEGO 2 UN
Ford
Racing
PCM50 -
39
UEGO 2 UN
Nernst Voltage signal. Connect to
pin 1 of Bosch UEGO sensor
C2-47
UEGO 2 IP
Ford
Racing
PCM50 -
16
UEGO 2 IP
Pumping Current signal. Connect to
pin 6 of Bosch UEGO sensor
C2-48
UEGO 2 IA
Ford
Racing
PCM50 -
28
UEGO 2 IA
Trim Current signal. Connect to pin 2
of Bosch UEGO sensor
C2-49
UEGO 2 HEAT
Ford
Racing
PCM50 -
35
UEGO 2 HEAT
Lowside switch for UEGO heater
control. Connect to pin 4 of Bosch
UEGO sensor. NOTE that pin 3 of the
Sensor is heater (+) and must be
power by a fused/switched 12V
supply.
C2-50
+12V_R8C_CPU
---
Battery Perm Power
Dedicated power
management CPU
Optional full time battery power.
MUST be powered before the ignition
switch input is triggered (See C1-65).
C2-51
Coil 7
5P "Coil
Driver 2" -
4
Coil on Plug Assembly
7 (COP7G)
25 mA max source
current
0-5V Falling edge fire. DO NOT
connect directly to coil primary.
Must use an ignitor OR CDI that
accepts a FALLING edge fire signal.
C2-52
Coil 8
5P "Coil
Driver 2" -
5
Coil on Plug Assembly
8 (COP8D)
25 mA max source
current
0-5V Falling edge fire. DO NOT
connect directly to coil primary.
Must use an ignitor OR CDI that
accepts a FALLING edge fire signal.
C2-53
Coil 9
---
Coil 9
25 mA max source
current
0-5V Falling edge fire. DO NOT
connect directly to coil primary.
Must use an ignitor OR CDI that
accepts a FALLING edge fire signal.
C2-54
Coil 10
---
Coil 10
25 mA max source
current
0-5V Falling edge fire. DO NOT
connect directly to coil primary.
Must use an ignitor OR CDI that
accepts a FALLING edge fire signal.
C2-55
HighsideSwitch_
2
2P
"Highside
Fuel
Pump" - 1
Fuel Pump
Multi-function pin
depending on hardware
configuration
See Setup Wizard page 'HighSide
Assigment Tables' for configuration
options. See 2D lookup table
'HS1_Table' for activation settings.
See Setup Wizard page 'User GPOs'
for default activation criteria.