AEM Infinity Supported Applications - Universal V8 Engine User Manual

Page 12

Advertising
background image

12

© 2014 AEM Performance Electronics

MSD Distributor + ATI AEM 24 Tooth + Honeywell Hall Effect Sensor

1. Modify and install mechanical advance distributor. (See

Modifying Mechanical Advance Distributor

, in

this document.)

2. Install ATI AEM Infinity crank trigger. (Note that an adjustable sensor mount is not provided with the

ATI crank trigger.) Position the crank sensor to be near the middle of its adjustment range while being
in between crank teeth with the engine at TDC. Set sensor air gap to .020”.

3. Wiring:

Crank Sensor – Honeywell Hall Effect Sensor

Cam Sensor – Modified MSD Distributor

Wire

Desc

Connect To

Wire

Desc

Connect To

Red

+12V sensor

power

Main relay power out

Black/

Purple

Cam signal + C1-48 Cam Pos Sens 1 VR+

Black

Sensor ground

C1-20 Sensor Ground

Black/

Orange

Cam signal -

C1-47 Cam Pos Sens 1 VR-

White

Crank signal

C1-21 Crk Pos Sens

Hall

Note: Use shielded tw isted pair w iring w /drain to ground.

Bare

Shield drain

Ground

Note: Use shielded w iring w ith drain to ground.

4. Load ATI 24 + Honeywell Hall base session and review Setup Wizard. (See

Setup Wizard

, in this

document.)

5. Sync ignition timing. (See

Syncing Ignition Timing

, in this document.)

Advertising