Pin

Hardware Ref.

7100-XXXX-62

7101-XXXX-63

Function

Hardware Specification

Notes

C2-35

Analog_In_22*

Spare Analog

Input

12 bit A/D, 100K pullup to 5V

0–5V analog signal. Use +5V Out pins as
power supply and Sensor Ground pins as
the low ref erence. Do not connect signals
ref erenced to +12V as this can
permanently damage the ECU. Normally
used as USB Logging Request input. *Pin
not populated in 30-3805 Univ ersal V8
Base harness.

C2-36

Analog_In_23*

Spare Analog

Input

12 bit A/D, 100K pullup to 5V

0–5V analog signal. Use +5V Out pins as
power supply and Sensor Ground pins as
the low ref erence. Do not connect signals
ref erenced to +12V as this can
permanently damage the ECU. Normally
used as Charge Out Pressure input. *Pin
not populated in 30-3805 Univ ersal V8
Base harness.

C2-37

Digital_In_6*

Spare Digital

Input

No pullup. Will work with TTL signals.

Input can be assigned to dif f erent pins.
See Setup Wizard page Input Function
Assignments f or input mapping options.

C2-38

Digital_In_7

Clutch Switch

No pullup. Will work with TTL signals.

See ClutchSwitch 1-axis table f or setup
options. Input can be assigned to
dif f erent pins. See Setup Wizard page
Input Function Assignments f or input
mapping options.

C2-39

Power Ground

Ground

Power Ground

Connect directly to battery ground.

C2-40

Power Ground

Ground

Power Ground

Connect directly to battery ground.

C2-41

CanH_Bout

CANH

Dedicated High Speed CAN Transceiv er

Not used

C2-42

CanL_Bout

CANL

Dedicated High Speed CAN Transceiv er

Not used

C2-43

LowsideSwitch_8

Engine Protect

Warning Out

Lowside switch, 4A max with internal
f ly back diode. Inductiv e load should NOT
hav e f ull time power.

Activ ates if any of the f ollowing f lags are
true: OilPressProtectOut,
LeanProtectOut, CoolantProtect. Output
can be assigned to other f unctions. See
Setup Wizard page LowSide Assignment
Tables f or additional options.

C2-44

LowsideSwitch_7*

LS7

Lowside switch, 4A max with internal
f ly back diode. Inductiv e load should NOT
hav e f ull time power.

Normally used as Spare GPO1 output.
*Pin not populated in 30-3805 Univ ersal
V8 Base harness.

C2-45

UEGO 2 VM

UEGO 2 VM

Bosch UEGO Controller

Virtual Ground signal. Connect to pin 5 of
Bosch UEGO sensor.

C2-46

UEGO 2 UN

UEGO 2 UN

Nernst Voltage signal. Connect to pin 1 of
Bosch UEGO sensor.

C2-47

UEGO 2 IP

UEGO 2 IP

Pumping Current signal. Connect to pin 6
of Bosch UEGO sensor.

C2-48

UEGO 2 IA

UEGO 2 IA

Trim Current signal. Connect to pin 2 of
Bosch UEGO sensor.

C2-49

UEGO 2 HEAT

UEGO 2 HEAT

Lowside switch f or UEGO heater control.
Connect to pin 4 of Bosch UEGO sensor.
NOTE that pin 3 of the Sensor is heater
(+) and must be power by a f used/
switched 12V supply .

C2-50

+12V_R8C_CPU

Battery Perm

Power

Dedicated power management CPU

Optional f ull time battery power. MUST be
powered bef ore the ignition switch input is
triggered. (See C1-65.)