AEM Infinity Supported Applications - Universal V8 Engine User Manual

Page 16

Advertising
background image

16

© 2014 AEM Performance Electronics

MSD Distributor + ATI Flying Magnet + Honeywell GT101 Sensor

1. Modify and install mechanical distributor. (See

Modifying Mechanical Advance Distributor

, in this

document.)

2. Install ATI Flying Magnet crank trigger. (Note that an adjustable sensor mount is not provided with the

ATI crank trigger.) Position the crank sensor to be near the middle of its adjustment range while being
in between magnet targets with the engine at TDC. Set sensor air gap to .053”.

3. Wiring:

Crank Sensor – Honeywell GT-101 Sensor

Cam Sensor – Modified MSD Distributor

Wire

Desc

Connect To

Wire

Desc

Connect To

Red

+12V sensor

power

Main relay power out

Black/

Purple

Cam signal +

C1-48 Cam Pos Sens 1 VR+

Black

Sensor ground

C1-20 Sensor Ground

Black/

Orange

Cam signal -

C1-47 Cam Pos Sens 1 VR-

White

Crank signal

C1-21 Crk Pos Sens

Hall

Note: Use shielded tw isted pair w iring w /drain to ground.

Note: Use shielded w iring w ith drain to ground.

4. Load ATI 12 + GT101 base session and review Setup Wizard. (See

Setup Wizard

, in this document.)

5. Sync ignition timing. (See

Syncing Ignition Timing

, in this document.)

Advertising