Section 7 - Lubrication and Maintenance

7-2

31200608

7.2

GENERAL MAINTENANCE INSTRUCTIONS

Prior to performing any service or maintenance on the telehandler, follow the
shut-down procedure on page 4-4 un
less otherwise instructed. Ensure
telehandler is level, for proper fluid readings.

• Clean lubrication fittings before lubricating.

• After greasing telehandler, cycle all functions several times to distribute

lubricants. Perform this maintenance procedure without attachment installed.

• Apply a light coating of engine oil to all linkage pivot points.

• Intervals shown are for normal usage and conditions. Adjust intervals for

abnormal usage and conditions.

• Drain engine and gear cases after operating when oil is hot.

• Check all lubricant levels when lubricant is cool, with the exception of the

transmission fluid. For ease of filling hydraulic reservoir, use a funnel with a hose
or flexible tube for best results.

Note: Be certain to check boom chain and tension every 250 hours and adjust as
required. Chain damage can occur if chain is not adjusted properly.

WARNING

CUT/CRUSH/BURN HAZARD. Do not perform service or maintenance on the
machine with the engine running, with the exception of the transmission oil level
check.