5 drive lockout system, 5 drive lockout system -18 – Lull 1044C-54 Series II Operation Manual User Manual

Page 52

Advertising
background image

Section 3 - Controls and Indicators

3-18

31200608

3.5

DRIVE LOCKOUT SYSTEM

Normal Mode

With boom below 20° (1), the drive system functions normally.

Restricted Mode

With boom between 20° and 40° (2), the system is in restricted mode.

• The transmission is limited to first and second gear.

Locked Mode

With boom above 40° (3), the system is in locked mode.

• The transmission is disengaged, stopping drive capabilities.

Override Mode

With boom above 40° (3) and the drive lockout override switch depressed and held
down, the system is in override mode.

• The transmission is limited to first gear.

• The rear oscillation lock system is in slow pivot mode. See page 3-17.

OV0270

2

3

1

5