RackSwitch G8000 Application Guide

Chapter 3: VLANs

„

53

BMD00041, November 2008

Figure 3-2

through

Figure 3-5

illustrate generic examples of VLAN tagging. In

Figure 3-2

,

untagged incoming packets are assigned directly to VLAN 2 (PVID = 2). Port 5 is configured
as a tagged member of VLAN 2, and port 7 is configured as an untagged member of VLAN 2.

N

OTE

The port assignments in the following figures are not meant to match the G8000.

Figure 3-2 Port-based VLAN assignment

As shown in

Figure 3-3

, the untagged packet is marked (tagged) as it leaves the switch through

port 5, which is configured as a tagged member of VLAN 2. The untagged packet remains
unchanged as it leaves the switch through port 7, which is configured as an untagged member
of VLAN 2.

Figure 3-3 802.1Q tagging (after port-based VLAN assignment)

Port 6

DA

SA

Data

CRC

BS45011A

Port 7

Port 8

Port 1

Port 4

Port 5

Port 2

Port 3

802.1Q Switch

PVID = 2

Untagged packet

Untagged member
of VLAN 2

Tagged member
of VLAN 2

B

efore

BS45012A

Port 6

Port 7

Port 8

Port 1

Port 4

Port 5

Port 2

Port 3

802.1Q Switch

Key

Priority
CFI
VID

- User_priority
- Canonical format indicator
- VLAN identifier

PVID = 2

Tagged member
of VLAN 2

Untagged memeber

of VLAN 2

After

DA

SA

Data

CRC

(*Recalculated)

Outgoing

untagged packet

(unchanged)

DA

SA

Data

CRC*

Tag

VID = 2

Priority

16 bits

3 bits

1 bits

12 bits

8100

CFI