RackSwitch G8000 Application Guide

Chapter 3: VLANs

„

57

BMD00041, November 2008

N

OTE

VLAN tagging is required only on ports that are connected to other switches or on ports

that connect to tag-capable end-stations, such as servers with VLAN-tagging adapters.

Server 1

This server is a member of VLAN 1 and has presence in only one IP
subnet. The associated switch port is only a member of VLAN 1, so
tagging is disabled.

Server 2

This server is a member of VLAN 1 and has presence in only one IP
subnet. The associated switch port is only a member of VLAN 1, so
tagging is disabled.

Server 3

This server belongs to VLAN 2, and it is logically in the same IP sub-
net as Server 5.
The associated switch port has tagging disabled.

Server 4

A member of VLAN 3, this server can communicate only with other
servers via a router.
The associated switch port has tagging disabled.

Server 5

A member of VLAN 1 and VLAN 2, this server can communicate only
with Server 1, Server 2, and Server 3.
The associated switch port has tagging enabled.

Enterprise
Routing switches

These switches must have all three VLANs (VLAN 1, 2, 3) configured.
They can communicate with Server 1, Server 2, and Server 5 via
VLAN 1.
They can communicate with Server 3 and Server 5 via VLAN 2.
They can communicate with Server 4 via VLAN 3.
Tagging on switch ports is enabled.