BernzOmatic GHA-120 User Manual

5' & 10' propane hose

Advertising
background image

GHA-060 & GHA-120

5' & 10' Propane Hose

DANGER

Failure to comply with these Warnings and

Instructions may result in an explosion or fire that

may cause property damage, serious personal injury

or death.

DO NOT DISCARD THESE WARNINGS AND INSTRUCTIONS

WARNING

For LP-Gas Only.

Read all instructions prior to installation and use.

Disconnection of old hose assembly or installation of

new hose assembly shall take place outdoors in a well-

ventilated area.

DO nOt

make modifications to this hose assembly.

If

the hose assembly

does not fit, return to the original

place of purchase and obtain the correct hose assembly

for your gas appliance.

Examine the new hose assembly for damage. Do not

use hose assembly

if damaged. If damaged return to

the original place of purchase.

Movement of the gas appliance, removal of old hose

assembly and installation of new hose assembly shall

only be done when appliance is cool.

DO nOt

use appliance until leak testing is complete and

any leaks are corrected.

3/8" Flare

Fitting

3/8" NPT

Installation Guidelines for Hose Assembly

turn burner control knob on portable LP-Gas appliance

1.)

to “off” position. turn LP-Gas “off” at cylinder by

turning the cylinder valve handle fully clockwise.

Route the hose through any required openings being

2.)

sure to avoid any areas that may cause wear or cut the

hose. Also avoid contact with any potential hot surfaces

on the appliance. Be sure that the hose does not create

a trip hazard.

Clean the male threads on the hose fitting. Apply teflon

3.)

®

tape to the male thread of the hose that will attach to

the regulator. Install to regulator using proper size

wrenches.

Connect the 3/8" flare fitting to the appliance by rotating

4.)

the fitting clockwise. tighten using the proper size

wrenches.

WARNING

When leak testing the connections:

Conduct leak test outdoors in a well ventilated area.

Do not smoke.

Do not use or permit sources of ignition in the area

while conducting a leak test.

Do not use matches, lighters or flame to check for leaks.

Do not use the appliance until any leaks are corrected.

Leak Testing

Before lighting your appliance, check for leaks by

1.)

applying a mild soapy water solution to all connections.

Slowly open the cylinder valve and check for leaks. the

appearance of bubbles indicates a leak.

Repair any leaks prior to lighting your appliance. If

2.)

you cannot stop a leak by additional tightening of the

connection, shut off the LP-Gas supply at the cylinder

valve and have an LP-Gas service person make the

needed repairs

WARNING

Materials used in the construction of this device

may contain brass (which may contain lead),

a chemical known to the State of California

to cause cancer, birth defects, or other

reproductive harm.

Combustion byproducts produced when using

this device contain chemicals known to the

State of California to cause cancer, birth defects

or other reproductive harm.

compra original y obtenga el conjunto de manguera

correcto para su artefacto a gas.

Examine el nuevo conjunto de manguera para verificar

que no esté dañado. no use el conjunto de manguera

si está dañado. Si estuviera dañado, devuélvalo al lugar

original de compra.

Sólo debe moverse el artefacto a gas, quitarse el

conjunto de manguera viejo e instalar un nuevo

conjunto de manguera cuando el artefacto esté frío.

nO use el artefacto hasta que se finalice la prueba de

fugas y se corrija cualquier fuga presente.

Adaptador de llama

3/8 de pulg. (9.5 mm)

3/8 de pulg.

(9.5 mm) NPT

Manguera de 5 pies (1.5 m) y

10 pies (3 m) para propano

PELIGRO

Si no se cumplen estas advertencias e instrucciones,

se pueden producir una explosión o un incendio

que pueden causar daños materiales, lesiones

personales graves o la muerte.

NO DESECHE ESTAS ADVERTENCIAS E INSTRUCCIONES

ADVERTENCIA

Para gas LP (propano líquido) únicamente.

Lea todas las instrucciones antes de instalar y usar.

La desconexión de un conjunto de manguera viejo o la

instalación de un nuevo conjunto de manguera deben

realizarse al aire libre en un área bien ventilada.

nO

modifique este conjunto de manguera. Si el

conjunto de manguera no calza, devuélvalo al lugar de

Pautas de instalación para el conjunto de manguera

Gire la perilla del control del quemador del artefacto

1.)

portátil de gas LP a la posición “off” (cerrado). Cierre el

paso de gas LP en el cilindro haciendo girar la manija de

la válvula del cilindro totalmente hacia la derecha.

Pase la manguera sobre cualquier abertura según sea

2.)

necesario, asegurándose de evitar cualquier área que

cause desgaste o cortes en la manguera. también evite

el contacto con cualquier superficie del artefacto que

pueda estar caliente. Asegúrese de que la manguera no

cree un peligro de tropiezo.

Limpie las roscas macho del adaptador de la

3.)

manguera. Aplique cinta de teflon

®

a la rosca macho

de la manguera que se conectará al regulador. Instale

en los reguladores usando llaves de los tamaños

correspondientes.

Conecte el adaptador de llama de 3/8 pulg. (9.5 mm) al

4.)

artefacto rotando el adaptador hacia la derecha. Ajuste

con una llave del tamaño correcto.

Advertising
This manual is related to the following products: