BernzOmatic GHA-320 User Manual

10' natural gas hose with quick connect, Danger, Warning

Advertising
background image

GHA-320

10' Natural Gas Hose with Quick Connect

DANGER

Failure to comply with these Warnings and Instructions

may result in an explosion or fire that may cause property

damage, serious personal injury or death.
DO NOT DISCARD THESE WARNINGS AND INSTRUCTIONS

WARNING

Read all instructions prior to installation and use.

This connection is intended for outdoor use only with portable

appliances that may be moved for convenience of operation.

This connection is for use with natural gas systems not

exceeding ½ PSI (3.45 kPa).

This connection must be of adequate length for the intended

application. The connection is designed for movement after

installation, but must not be kinked, twisted or torqued.

Periodic visual inspection should be made to determine that

the connection is suitable for continued use.

Contact with damaging foreign objects or substances must be

avoided.

All adapters (unions) supplied with the connector must be

used. No attempt shall be made to connect the fittings on

the connector directly to the threaded rigid pipe ends on the

equipment manifold or the outlet of the natural gas piping

system.

DO NOT make modifications to this hose assembly. If the hose

assembly does not fit, return to the original place of purchase

and obtain the correct hose assembly for your gas appliance.

Examine the new hose assembly for damage. Do not use hose

assembly if damaged. If damaged return to the original place

of purchase.

DO NOT use appliance until leak testing is complete and any

leaks are corrected.

Sleeve

Coupling

Socket

Male Fitting

3/8" Flare Fitting

Natural Gas Hose

Installation Guidelines for Natural Gas Hose Assembly

Turn off natural gas supply at the shut-off valve on the gas

1.)

source piping.

Apply Teflon

2.)

®

tape to the male threads on the gas source piping.

Connect the female threaded end of the coupling socket to the

3.)

gas source piping in accordance with NFPA-54/ANSI Z223.1

Fuel Gas Code.

Turn on natural gas supply at the valve on the gas source

4.)

piping and check for leaks.

Connect the 3/8" flare fitting on the natural gas hose to the

5.)

appliance’s gas manifold or burner in accordance with the

appliance manufacturer’s instructions.

Connect the natural gas hose to the gas supply line by pushing

6.)

back the sleeve on the socket and inserting the male fitting on

the hose into the socket and releasing the sleeve. Push male

fitting until the sleeve snaps forward locking the male fitting in

the socket. Note: This automatically initiates the flow of natural

gas to the appliance. Leak test the hose connections.

WARNING

When leak testing the connections:

Conduct leak test outdoors in a well ventilated area.

Do not smoke.

Do not use or permit sources of ignition in the area while

conducting a leak test.

Do not use matches, lighters or flame to check for leaks.

Do not use the appliance until any leaks are corrected.

Leak Testing

Before lighting your appliance, check for leaks by applying a

1.)

mild soapy water solution to all connections. The appearance

of bubbles indicates a leak. Rinse with clean water after leak

testing to remove any potential corrosive residue.

Repair any leaks prior to lighting your appliance. If you cannot

2.)

stop a leak by additional tightening of the connection, turn off

the natural gas supply at the shut-off valve on the gas source

piping. Disconnect the natural gas hose from gas supply and

have a gas service person make the needed repairs.

WARNING

Materials used in the construction of this device may

contain brass (which may contain lead), a chemical

known to the State of California to cause cancer, birth

defects, or other reproductive harm.

Combustion byproducts produced when using this

device contain chemicals known to the State of

California to cause cancer, birth defects or other

reproductive harm.

periódicas para determinar que la conexión sea apta para

continuar siendo usada.

Debe evitarse el contacto con objetos o substancias extraños

que la dañen.

Deben usarse todos los adaptadores (uniones) proporcionados

con el conector. No debe intentarse conectar los adaptadores

en los conectores directamente a los extremos rígidos de las

tuberías roscadas del distribuidor del equipo ni a la salida del

sistema de tubería de gas natural.

NO modifique este conjunto de manguera. Si el conjunto de

manguera no calza, devuélvalo al lugar de compra original y

obtenga el conjunto de manguera correcto para su artefacto a gas.

Examine el nuevo conjunto de manguera para verificar que

no esté dañado. No use el conjunto de manguera si este se

encuentra dañado. Si estuviera dañado, devuélvalo al lugar

original de compra.

NO use el artefacto hasta que se finalice la prueba de fugas y

se corrija cualquier fuga presente.

Manguito

Acoplamiento

Adaptador macho

Adaptador de llama

3/8 pulg. (9.5 mm)

Manguera de gas natural

Manguera de 10 pies (3 m) para gas

natural con conexión rápida

PELIGRO

Si no se cumplen estas advertencias e instrucciones, se

pueden producir una explosión o un incendio que pueden

causar daños materiales, lesiones personales graves o

la muerte.
NO DESECHE ESTAS ADVERTENCIAS E INSTRUCCIONES

ADVERTENCIA

Lea todas las instrucciones antes de instalar y usar.

Esta conexión está diseñada para uso al aire libre únicamente

con artefactos portátiles que pueden moverse para un cómodo

funcionamiento.

Esta conexión es para uso con sistemas de gas natural que no

excedan ½ PSI (3.45 KPA).

Esta conexión debe ser de largo adecuado para la aplicación

para la cual se va a usar. La conexión está diseñada para ser

movida después de la instalación, pero no puede torcerse,

retorcerse ni girarse. Deben realizarse inspecciones visuales

Pautas de instalación para el conjunto de manguera

Cierre el suministro de gas natural en la válvula de cierre de la

1.)

tubería de la fuente de gas.

Aplique cinta Teflon

2.)

®

a las roscas macho de la tubería de la

fuente de gas.

Conecte el extremo roscado hembra del acoplamiento a la

3.)

tubería de la fuente de gas de acuerdo con el Código de gas

combustible NFPA-54/ANSI Z223.1.

Abra el suministro de gas natural en la válvula de la tubería de

4.)

fuente de gas y verifique que no existan fugas.

Conecte el adaptador de llama de 3/8 pulg. (9.5 mm) de la

5.)

manguera de gas natural al distribuidor de gas o quemador

del artefacto de acuerdo con las instrucciones del fabricante

del artefacto.

Conecte la manguera de gas natural a la línea de suministro

6.)

empujando el manguito hacia atrás en el conector,

introduciendo el adaptador macho de la manguera en el

conector y soltando el manguito. Empuje el adaptador

macho hasta que el manguito calce a presión hacia adelante

trabando el adaptador macho en el conector. Nota: Esto inicia

automáticamente el flujo de gas natural al artefacto. Verifique

que estas conexiones no tengan fugas.