Condux APS75 Underground Pulling Trailer User Manual

Page 13

Advertising
background image

13

3. CLOCK SET - This screen displays Date

and Time. Press and hold 56 together

to enter EDIT mode. Use the 4 button

to move between units. Use the 56 to

change the value of each unit.

NOTE:

Recorded data is time stamped, so it

is important to have the clock set in

order to be able to match data to a

specific pull (Figure 5).

4. RAW DATA - Displays raw data for

trouble shooting purposes. The data

shown is Work Pressure, Charge

Pressure, Reel Pressure, Engine RPM,

and Joystick Actuation.

5. HP LIMITING ON/OFF - Turns HP

Limiting feature on or off. HP Limiting

controls pump stroke when running at

high speed to eliminate engine stall due

to overloading. When running in the

mid throttle range, it may be preferable

to have this feature turned off to avoid

having the controller attempt to reduce

pump stroke.

C. RESET LENGTH

(Figure 6)

The Distance Counter on the APS75

Electronic Control maintains length data,

even after machine shut down. To reset the

counter to 0 at any time, press and hold the

RESET LENGTH button until the footage

returns to 0.

D. TENSION LIMIT

(Figure 7)

The APS75 Electronic Controls allow the

user to limit the pulling tension applied to

the cable.

• Press and hold LIMIT button until Limit

screen is displayed.

• Limit status is displayed at the top of

the screen as LIMIT OFF or LIMIT ON.

• Scroll to LIMIT, and press 4. Use the

56

arrows to change the Tension

Limit value, and the 4 button to switch

between 100's and 1000's digits.

• Press RETURN to return to the main

LIMIT screen.

• Scroll to LIMIT ON/OFF and press 4

to turn Limit feature on or off. - Status

displayed at the top of the screen will

change.

• Press RETURN to return to the Main

screen.

Figure 7. Tension Limit

Figure 6. Reset Length

Figure 5. Clock Set Screen

Figure 8. Emergency Stop Screen