PROBLEM:

CAUSE:

SOLUTION:

The clogged filter

warning light turns on.

Hydraulic oil temperature

too low

Allow oil to warm up by

running the engine at

idle for several minutes.

The oil is too thick

with respect to the

environmental conditions

Use oil with lower

viscosity as per the

indications in the

instruction manual

Clogged hydraulic oil filter

Replace

When starting the

control lever, the bull

wheels don't work.

E-Stop has been pressed.

Pull up depressed

E-Stop Button. Follow

instructions on Control

Screen to reset the

machine

Tension Limit has been

exceeded.

Follow instructions on

Control Screen to reset

the machine. If Tension

Limit continues to be

exceeded, increase

Limit Value or shut off

Limit Control to continue

pull.

The joystick is not sending

a signal to the controller.

Verify that the joystick

is sending out an

appropriate signal by

pressing SETUP>RAW

DATA and looking at

Joystick. Move joystick

and verify that the value

changes with joystick

stroke. - technical

assistance.

Defective pump servo

control

Verify the electric

voltage – technical

assistance

When moving the

control lever, the bull-

wheels rotate but the

rope doesn’t move

– slips on the bull-

wheels.

Reel winder pressure not

sufficient

Increase the reel winder

pressure
Replace the adjusting

valve for the reel winder

pressure
Reel winder pump

problem – technical

assistance

Advertising