PROBLEM:

CAUSE:

SOLUTION:

Excessive hydraulic oil

temperature.

The fan of the hydraulic oil

doesn’t work

Verify the electric

contact of the

temperature bulb on

the radiator
Verify the electric

contact of the ventilator

ignition selector on the

control panel

Overused machine

Wait for oil to

cool. Hydraulic oil

cooler should run

automatically when oil

temperature exceeds

temp limit.

A unexpected stop

happens when

returning to center

position with the

control lever

Hydraulic pump with

defective zero setting

Carry out the hydraulic

and mechanic zero

setting – technical

assistance

23

PROBLEM:

CAUSE:

SOLUTION:

Diesel engine turns off

during operations.

Engine oil pressure too low

(Light on Kohler Controller)

Add engine oil
Defective sensor

– check contacts /

replace
Engine anomaly –

technical assistance

Engine cooling liquid

temperature is too high

(Light on Kohler Controller)

Add cooling liquid
Defective sensor

– check contacts /

replace
Engine overheating –

technical assistance

Engine has been

overloaded and stalled

When engine starts to

slow, reduce joystick

stroke.