Troubleshooting guide – Condux APS75 Underground Pulling Trailer User Manual

Page 21

Advertising
background image

21

3.

9.

PROBLEM:

CAUSE:

SOLUTION:

The diesel engine starter

doesn’t work.

Burned fuse

Replace

Run down battery (Light on

Kohler Controller)

Recharge or replace

Disconnected contacts of the

ignition system / starter

Reconnect

Oxidised contacts of the

ignition system / starter

Clean or spray with a

suitable vaporiser

Starter out of order

Replace / Technical

assistance

Diesel engine doesn’t

work.

The ignition key not turned

to start position

Turn ignition key

clockwise to start

position and hold until

the engine starts

The glow plug indicator

light isn’t turned off (On

Kohler Controller)

Wait for the glow plug

indicator light to turn

off before starting

Fuel problem

Check the fuel level in

the tank
Check the fuel filter

Diesel engine turns

off when releasing the

ignition key.

Check of the engine oil

pressure

Add engine oil
Defective sensor–

check contacts /

replace
Engine anomaly –

technical assistance

Check of the engine cooling

liquid temperature

Add cooling liquid
Defective sensor–

check contacts /

replace
Engine anomaly –

technical assistance

The charge pressure

is lower than 24 bar –

340psi

Clogged hydraulic oil filter

Replace

Defective pump

Technical assistance

Diesel engine doesn’t

increase rpm

Disconnected accelerator

cable

Verify and if necessary

replace

Troubleshooting Guide