Condux APS75 Underground Pulling Trailer User Manual

Page 14

Advertising
background image

14

• Tension Limiting status is displayed in the upper right hand corner of the Main

Screen (Figure 2)

• If Tension Limiting is turned ON, and the set tension limit is exceeded

during a pull, the controller will disable the pump by forcing it to neutral. The

Screen will display a red message instructing the user to return the joystick

to Neutral. Press the button labeled RESET to return to the main screen.

(Figure 8)

NOTE: The system will not reset unless the joystick is in the

Neutral position.

E. RECORDING PULL DATA

The APS75 Electronic Controls allow the

user to record pull data, including time of

pull, pull distance, and pulling tensions.

Data can be downloaded to a computer

or exported via a USB flash drive. The

Electronic Display holds 16MB of onboard

flash memory, which is space for over 100

hours of pull data. Once full, the Recorder

will overwrite the oldest data in its memory.

(Figure 9)

• Press and hold RECORD button until

Record screen is displayed.

• Record status is displayed at the top of the RECORD screen as "RECORD

OFF" or "RECORD ON".

• To begin recording a new pull, scroll to START NEW and press SELECT.

• To continue recording a pull that has been interupted, select

CONTINUE PREV.

• Press RETURN to return to the Main screen.

• If the Record function is turned OFF, RECORDING OFF will be displayed

in a red block on the Main screen. If the Recording function is turned ON,

RECORDING will be displayed on the Main screen, along with the sample

rate at which points are being recorded (Figure 2)

• At the end of a pull, select STOP RECORDING to close the file.

F. ExPORTING DATA

Pull Data can be exported from the

APS75 Control Panel through a USB

port located in the Mobile Joystick

docking station. (Figure 10) Please see

the included addendum for additional

details for exporting and viewing data.

Figure 9. Record Screen

Figure 10. USB Port