Specifications – Det-Tronics PIR9400 PointWatch Infrared Hydrocarbon Gas Detector User Manual

Page 4

Advertising
background image

2

95-8440

9.3

SPECIFICATIONS

PointWatch Gas Detector (PIR

9400

)

INPUT VOLTAGE—

24

Vdc nominal. Operating range is

18

to

30

Vdc.

POWER CONSUMPTION (Watts)—
Input Voltage:

18

Vdc

24

Vdc

30

Vdc

Nominal

3.5

4.6

6.2

Maximum

4.0

5.5

7.0

DETECTION RANGE—

0

to

100%

LFL.

GASES —
The Model PIR

9400

Detector is approved to Methane, but

most flammable hydrocarbon vapors (ethane, ethylene,

propane, butane, and propylene) are also detectable.

Methane gas detection is the factory default gas type

setting. Reference the “IR Module Removal and Gas

Selection” section of this manual for alternate gas type

settings.

CURRENT OUTPUT (NON-ISOLATED)—
Linear

0–20

mA current source.

• 4–20

mA output indicates

0

to

100%

LFL detection

range (for linearized gases)

• 23.2

mA indicates over-range condition

• 0–2.4

mA levels indicate calibration, fault and

fouled optics conditions.

Refer to Table

1

for a detailed description of current

outputs.

Maximum loop resistance:

580

ohms at

24

Vdc.

See Figure

1

for further information.

NOTE

The following specifications for Accuracy, Stability
and Repeatability are based on

0

to

100%

LFL

methane.

ACCURACY (Room Temperature)—

±3%

LFL from

0

to

50%

LFL,

±5%

LFL from

51%

to

100%

LFL.

RESPONSE TIME (Seconds)—

N·m T

90

Multilayered aluminum weather baffle

With hydrophobic filter

7 14.4

Without hydrophobic filter

5 10

Polyphthalamide (PPA) weather baffle

With hydrophobic filter

6 16

Without hydrophobic filter

2 3

STABILITY—

Temperature

Zero:

±2%

LFL from

40°

F to +

167°

F (–

40°

C to +

75°

C)

Span:

±5%

LFL at

50%

LFL from

–13°

F to +

167°

F (

–25°

C to

+75°

C)

±10%

LFL at

50%

LFL from

40°

F to –

13°

F (–

40°

C to

–25°

C).

Time (

10

months)

±2%

LFL (Det-Tronics verified).

REPEATABILITY (Room Temperature)—
Zero:

±1%

LFL

Span:

±2%

LFL at

50%

LFL

(Det-Tronics verified).

C1964

18

20

22

24

POWER SUPPLY VOLTAGE (VDC)

26

28

30

32

MAXIMUM LOOP RESISTANCE (OHMS)

400

500

600

700

800

900

LOOP RESISTANCE (OHMS)

Figure 1—4 to 20 mA Current Loop Resistance

Table 1—Current Loop Output Levels and Corresponding Status

Indications

Current Level

Status

23.2 mA

Over-range

20.0 mA

Full scale (

100% LFL)

4.0 mA

Zero gas level (

0% LFL)

2.2 mA

Zero calibration in progress

2.0 mA

Span calibration in progress

1.8 mA

Calibration complete - remove gas

1.6 mA

Calibration fault

1.0 mA

Fouled optics

0.8 mA

24 Vdc line low (less than 17.5 Vdc)

0.6 mA

Calibrate input active at power-up

(probable wiring fault)

0.4 mA

Active channel fault

0.2 mA

Reference channel fault

0.0 mA

CPU system fault, warmup

Advertising