Chapter 6: wiring, Chapter 6, Wiring – ElmoMC Gold Line Digital Servo Drives-Gold Solo Whistle User Manual

Page 18: N chapter 6: wiring

Advertising
background image

Gold Solo Whistle Installation Guide

MAN-G-SOLWHIIG-EC (Ver. 1.500)

|The Gold Solo Whistle Connection Diagrams|

www.elmomc.com

18

Table of Contents

Chapter 6:

Wiring

Once the product is mounted, you are ready to wire the device. Proper wiring, grounding and
shielding are essential for ensuring safe, immune and optimal servo performance of the drive.

The following table legend describes the wiring symbols detailed in all installation guides.

Wiring Symbol

Description

Earth connection (PE)

Protective Earth Connection

Common at the Controller

Shielded cable with drain wire.
The drain wire is a non-insulated wire

that is in direct contact with the braid
(shielding).
Shielded cable with drain wire
significantly simplifies the wiring and
earthing.

Shielded cable braid only, without
drain wire.

Twisted-pair wires

Encoder Earthing.
The cable`s shield is connected to the
chassis (PE) in the connector.
Earthing the Encoder and connecting
the Earth (PE) to the drive COMRET is

mandatory to insure reliable
operation, high noise immunity and
rejection of voltage common mode
interferences.

Advertising