6.3. Main and Auxiliary Power

The Gold Solo Whistle receives power from main and auxiliary supplies and delivers power to the
motor.

6.3.1.

Description

This section describes the Main and Auxiliary Power for power ratings 200V and 100V, and provides
details for the optional Backup (Auxiliary) Supply.

The Gold Solo Whistle Power rating is 12 to 195 VDC

There are Two power ratings for Gold Solo Whistle; 100V and 200V:

For power rating 200V
Two power isolated DC power sources are required, main power 12 - 195V and Auxiliary Power
12-95V for the logic.

For power rating of 100V
Single DC Power Supply - Power to the Gold Solo Whistle is provided by a 12–95 VDC single
isolated DC power source (not included with the Gold Solo Whistle). A “smart” control-supply
algorithm enables the Gold Solo Whistle to operate with only one power supply with no need
for an auxiliary power supply for the logic.

Optional Backup (Auxiliary) Supply
If backup functionality is required in case of power loss, e.g., to keep the original position, a
12–95 VDC external isolated supply should be connected (via the Gold Solo Whistle’s VL+
terminal). This is more flexible than the requirement for 24 VDC supply.
If backup is not needed, a single power supply is used for both the power and logic circuits.
There are two voltage ratings of the Gold Solo Whistle, therefore the correct power supply
must be used, according to the maximum operating voltage of the Gold Solo Whistle. Refer to
section 4.2 Technical Data.