4.1. Physical Specification

Feature

Units

All Types

Weight

g (oz)

106 g (3.74 oz)

Dimension

mm (in)

73.4 x 46.5 x 36.22 mm (2.89" x 1.83" x 1.425")

Mounting method

Panel Mounted

4.2. Technical Data

Feature

Units

1/100 2.5/100 5/100 10/100 15/100 20/100

Minimum supply voltage

VDC

12

Nominal supply voltage

VDC

85

Maximum supply voltage

VDC

95

Maximum continuous power

output

W

80

200

400

800

1200

1600

Efficiency at rated power (at

nominal conditions)

%

> 99

Maximum output voltage

> 95% of DC bus voltage at f = 22 kHz

Auxiliary power supply

VDC

12 to 95 VDC

(up to 6 VA inc. 5 V/2 x 200 mA for encoder)

Amplitude sinusoidal/DC

continuous current

A

1.0

2.5

5

10

15

20

Sinusoidal continuous RMS

current limit (Ic)

A

0.7

1.8

3.5

7

10.6

14.1

Peak current limit

A

2 x Ic

Table 1: Power Rating

Note on current ratings:

The current ratings of the Gold Solo Whistle are given in units of DC

amperes (ratings that are used for trapezoidal commutation or DC motors). The RMS (sinusoidal
commutation) value is the DC value divided by 1.41.