H/r = ρ(p, R] = ρ, Hr = rρ – ElmoMC Multi-Axis Motion Controller-Maestro Motion Control User Manual

Page 34: R = hρ

Advertising
background image

Motion Library Tutorial

Switch Radius Calculation

MAN-MLT (Ver 2.0)

2-13

Figure

2-7

This condition is not always sufficient. Adequacy depends on arc and line lengths. If the
circle’s center projection on the line

L

belongs to the line segment (

P

1

L

)

and an

intersection point of the continued perpendicular with the circle arc belonging to the
circle segment

P

2

C

then (2.2.1.2-1)

is sufficient

.

If projection of the circle init point

P

1

belongs to the line segment -

P

5

L

(Figure 2-

8), use the following proportion

h/r = ρ(P

3

, O

c

)/[ρ(P

1

, P

3

) – r] = ρ

1

/(ρ

2

– r)

(2.2.1.2-2)

where

P

3

is the point of intersection of the line

(P

1

,O

c

)

with the line

L.

As init point of

the circle

P

1

and a circle center are known,

P

3

can be determined

.

The length

h

of the

perpendicular dropped from the circle center

O

c

on the line

L

can be also found by

(2.2.1.2-4) or another method.

From (2.2.1.2-2) the results are

2

– hr = rρ

1

=>

r = hρ

2

/(ρ

1

+ h)

(2.2.1.2-3)

Advertising