Motion Library Tutorial

Switch Radius Calculation

MAN-MLT (Ver 2.0)

2-27

Figure 2-24

2.2.3.2

Line parallel to the circle arc init radius

a) Line direction coincides with the direction of the init radius

In this simple case (Figure 2-25) maximum switch radius is equal to the distance between
line L and circle arc init radius. This distance is equal to length of perpendicular

h

dropped

from the circle arc center

O

c

on the line

L.

To define it we can use the same formula

(

2.2.1.1-4).

Figure 2-2-25a

b) Line direction is opposite to the direction of the init radius