Scroller Calibration Column

Calibration can also be done from the scroller calibration column.

The calibration information, that is displayed, is the DMX address that puts the frame into its center
position. Information in the calibration column can be manually edited by clicking on it and typing in
a new DMX address.

Pressing the softkey {Clear Calib} will clear out the calibration data for the whole scroller wheel,
returning it to the default data.

Scroller wheels and their calibration data can be copied to other channels.

[1] {Copy Scroller} [2] [Enter] - copies the scroller and calibration data from channel 1 to

channel 2.

Scrollers that have calibrated data will display a “~” after their name.

The {Calibrate} button will now only appear on scroller

parameters that are currently not at the center of a
frame.

N o t e :

Calibration data will only be applied to scroller wheels that are assigned to a

channel. Data will not be displayed when viewing a wheel with an empty command

line.

N o t e :

Calibration data can be returned to its default by clicking on the data and pressing

[Clear]. If you are entering in new data and hit [Clear], the data will return to the

default and not any previously calibrated data.

Values in grey are default

data, and the values in blue

are calibrated data.