Operating Instructions Safety Switch CET.-AR-...-AH-...

11

Escape release (optional)

Important:

 Ì

The escape release is not a safety function.

 Ì

The machine manufacturer must select and use a suitable release (escape 
release, emergency unlocking, etc.) for a specific application. A risk assess-
ment appraisal is required for this purpose. It may be necessary to take 
specifications from a product standard into account.

 Ì

The correct function must be checked at regular intervals.

 Ì

Loss of the release function due to tension on the actuator. The door must 
not be under tension during release.

 Ì

Please observe the notes on any enclosed data sheets.

The escape release is used to open a locked safety guard from the inside (see 

dimension drawing in the section Technical data).
Fit escape release such that operation, inspection and maintenance are possible.

Using the escape release

 Ì

Press the red release knob to the stop

¨

The safety device can be opened

Pull the knob out again to reset.
The monitoring output OUT is switched off; OUT D can assume an undefined state.  

Open the safety door and close it again after resetting the escape release. The 

device will then operate normally again.