Operating Instructions Safety Switch CET.-AR-...-AH-...

40

Technical data

Note:

If a product data sheet is included with the product, the information on the data 

sheet applies in case of discrepancies with the operating instructions.

Technical data for safety switch CET.-AR-C..-AH-...

Parameter

Value

Unit

min.

typ.

max.

General
Material, slide

Stainless steel

Material, safety switch housing

Die-cast aluminum

Installation position

Any (recommendation: switch head downward)

Degree of protection

with plug connector M12

IP67

with plug connector RC18

IP65

(screwed tight with the related mating connector)

Safety class

III

Degree of contamination

3

Mechanical life

1 x 10

6

 operating cycles

Ambient temperature at U

B

-20

-

+55

°C

Actuator approach speed, max.

20

m/min

Locking force F

max

6500

N

Locking force F

Zh

in acc. with GS-ET-19

F

Zh

 = F

max

/1.3 = 5000

N

Weight

approx. 1.0

kg

Degrees of freedom (actuator in recess) X, Y, Z

X, Y ± 5; Z ± 4

mm

Connection type (depending on version)

2 plug connectors M12, 5 and 8-pin

1 plug connector RC 18, 19-pin (as yet no UL approval)

Operating voltage U

B

 (reverse polarity protected, regulated, 

residual ripple < 5%)

24 ± 15% (PELV)

V DC

Current consumption I

B

80

mA

For the approval according to UL the following applies

Operation only with UL class 2 power supply, or equivalent measures

Switching load according to UL

DC 24 V, class 2

External fuse (operating voltage U

B

)

0.25

-

2

A

External fuse (solenoid operating voltage U

CM

)

0.5

-

8

A

Rated insulation voltage U

i

-

-

75

V

Resilience to vibration

In acc. with EN 60947-5-2

EMC protection requirements

In acc. with EN IEC 60947-5-3

Safety outputsOA/OB

Semiconductor outputs, p-switching, short circuit-proof

- Output voltage U

OA

/U

OB

1)

V DC

 HIGH 

U

OA

/U

OB

U

B

 - 1.5

-

U

B

 LOW 

U

OA

/U

OB

0

-

1

Switching current per safety output

1

-

200

mA

Utilization category according to EN 60947-5-2

DC-13 24V 200mA

Caution: outputs must be protected with a free-wheeling diode in case of inductive loads

Switching frequency

0.5

Hz

Repeat accuracy R acc. to EN IEC 60947-5-3

≤ 10

%

Monitoring outputsOUT and OUT D (optional)

p-switching, short circuit-proof

Output voltage

0.8 x U

B

-

U

B

V DC

Max. load

-

-

50

mA

Teach-in input J or input feedback loop Y
HIGH

15

-

U

CM

V

LOW

0

-

1

Solenoid
Solenoid operating voltage U

CM

 (reverse polarity protected, 

regulated, residual ripple < 5%)

DC 24 V +10%/-15%

Current consumption solenoid I

CM

480

mA

Power consumption

10

W

Duty cycle

100

%

Freely configurable LEDs

2)

LED1 red, LED2 green

Operating voltage

20.4

-

26.4

V DC

Reliability values according to EN ISO 13849-1

Head downward or horizontal

Head upward

Category

4

3

Performance Level (PL)

e

e

PFH

d

3.1 x 10

 -9

 / h

4.29 x 10

 -8

 / h

Mission time

20

20

years

1) Values at a switching current of 50 mA without taking into account the cable lengths.