Connector assignment safety switch CET-AR with

plug connectors 2 x M12

Version without door monitoring output (CET1/2)

Version with door monitoring output (CET3/4)

wiring diagram A

Plug connectors

(view of connection side)

PIN

Designation

Function

Wire color

Connection cable

1)

2 x M12

S2.5

S1.8

S1.5

S1.6

S1.7

S1.2

S2.4

S2.3

S2.1

S2.2

S1.4

S1.3

S1.1

S 1.1

IB

Enable input for channel 2

WH

S 1.2

U

B

Operating voltage AR electronics, 24 V DC

BN

S 1.3

OA

Safety output, channel 1

GN

S 1.4

OB

Safety output, channel 2

YE

S 1.5

OUT

Door monitoring output

GY

S 1.6

IA

Enable input for channel 1

PK

S 1.7

0 V U

B

Operating voltage AR electronics 0 V

BU

S 1.8

RST

Reset input

RD

S 2.1

0 V U

CM

Operating voltage of guard locking solenoid 0 V

BN

S 2.2

LED 1

LED 1 red, freely configurable, 24 V DC

WH

S 2.3

LED 2

LED 2 green, freely configurable, 24 V DC

BU

S 2.4

U

CM

Operating voltage of guard locking solenoid, 24 V DC

BK

S 2.5

J

Version with teach-in input:

To teach-in a new actuator, connect to 24 V DC; in nor-

mal operation connect to 0 V.

GY

Y

Version with feedback loop:

If the feedback loop is not used, connect to 24 V DC

B

-

Version without feedback loop and without teach-in input:

This connection must be connected to 0 V.

1) Only for standard EUCHNER connection cable

wiring diagram B

Plug connectors

(view of connection side)

PIN

Designation

Function

Wire color

Connection cable

1)

2 x M12

S2.5

S1.8

S1.5

S1.6

S1.7

S1.2

S2.4

S2.3

S2.1

S2.2

S1.4

S1.3

S1.1

S 1.1

IB

Enable input for channel 2

WH

S 1.2

U

B

Operating voltage AR electronics, 24 V DC

BN

S 1.3

OA

Safety output, channel 1

GN

S 1.4

OB

Safety output, channel 2

YE

S 1.5

OUT

Door monitoring output

GY

S 1.6

IA

Enable input for channel 1

PK

S 1.7

0 V U

B

Operating voltage AR electronics 0 V

BU

S 1.8

RST

Reset input

RD

S 2.1

0 V U

CM

Operating voltage of guard locking solenoid 0 V

BN

S 2.2

OUT D

Door monitoring output

WH

S 2.3

LED 1

LED 1 red, freely configurable, 24 V DC

BU

S 2.4

U

CM

Operating voltage of guard locking solenoid, 24 V DC

BK

S 2.5

J

Version with teach-in input:

To teach-in a new actuator, connect to 24 V DC; in nor-

mal operation connect to 0 V.

GY

Y

Version with feedback loop:

If the feedback loop is not used, connect to 24 V DC

B

-

Version without feedback loop and without teach-in input:

This connection must be connected to 0 V.

1) Only for standard EUCHNER connection cable

Advertising