23

Connector assignment safety switch CET-AR with

plug connector RC18

wiring diagram D

Plug connectors

(view of connection side)

PIN

Designation

Function

Wire color

Connection cable

1)

RC18

With screen 

bonding clamp

18

19

15

12

11

9

5

4

3

2

1

17

16

14

13

6

10

8

7

1

U

CM

Operating voltage of guard locking solenoid, 24 V DC

VT

2

IA

Enable input for channel 1

RD

3

IB

Enable input for channel 2

GY

4

OA

Safety output, channel 1

RD/BU

5

OB

Safety output, channel 2

GN

6

U

B

Operating voltage AR electronics, 24 V DC

BU

7

RST

Reset input

GY/PK

8

OUT D

Door monitoring output (only CET3-AR and CET4-AR)

GN/WH

9

-

n.c. 

YE/WH

10

OUT

Door monitoring output

GY/WH

11

-

n.c.

BK

12

FE

Function earth

GN/YE

13

J

Version with teach-in input:

To teach-in a new actuator, connect to 24 V DC; in nor-

mal operation connect to 0 V.

PK

Y

Version with feedback loop:

if the feedback loop is not used, connect to 24 V DC

-

Version without feedback loop and without teach-in input:

This connection must be connected to 0 V.

14

-

n.c.

BN/GY

15

LED 1

LED 1 red, freely configurable, 24 V DC

BN/YE

16

LED 2

LED 2 green, freely configurable, 24 V DC

BN/GN

17

-

n.c.

WH

18

0V U

CM

Operating voltage of guard locking solenoid 0 V

YE

19

0V U

B

Operating voltage AR electronics 0 V

BN

1) Only for standard EUCHNER connection cable

wiring diagram C

Plug connectors

(view of connection side)

PIN

Designation

Function

Wire color

Connection cable

1)

2 x M12

S2.5

S1.8

S1.5

S1.6

S1.7

S1.2

S2.4

S2.3

S2.1

S2.2

S1.4

S1.3

S1.1

S 1.1

IB

Enable input for channel 2

WH

S 1.2

U

B

Operating voltage AR electronics, 24 V DC

BN

S 1.3

OA

Safety output, channel 1

GN

S 1.4

OB

Safety output, channel 2

YE

S 1.5

OUT

Door monitoring output

GY

S 1.6

IA

Enable input for channel 1

PK

S 1.7

0 V U

B

Operating voltage AR electronics 0 V

BU

S 1.8

RST

Reset input

RD

S 2.1

0 V U

CM

Operating voltage of guard locking solenoid 0 V

BN

S 2.2

OUT D

Door monitoring output

WH

S 2.3

OUT

Door monitoring output

BU

S 2.4

U

CM

Operating voltage of guard locking solenoid, 24 V DC

BK

S 2.5

-

Not used

1) Only for standard EUCHNER connection cable