Operating Instructions Safety Switch CET.-AR-...-AH-...

12

Wire front release (optional)

Important:

 Ì

The wire front release is not a safety function.

 Ì

The wire front release is non-latching and therefore must not be used as an 
escape release unless the machine manufacturer itself provides a detent 
mechanism. The machine manufacturer must select and use a suitable re-
lease (escape release, emergency unlocking, etc.) for a specific application. 
A risk assessment appraisal is required for this purpose. It may be neces-
sary to take specifications from a product standard into account.

 Ì

Loss of the release function due to tension on the actuator. The door must 
not be under tension during release.

 Ì

The correct function must be checked at regular intervals.

The wire front release permits remote release of the guard locking via a pull rope. 

Flexible routing of the pull rope permits release of the guard locking in inaccessible 

installation situations.

Mounting the wire front release

Important:

 Ì

Loss of the release function due to mounting errors, damage or wear. 

 Ì

Check the release function every time after mounting.

 Ì

When routing the wire front release, ensure that it operates smoothly. 

 Ì

Observe the min. bending radius (100 mm) and minimize the number of 
bends.

 Ì

The switch is not allowed to be opened.

 Ì

Observe the notes on the enclosed data sheets.