Operating Instructions Safety Switch CET.-AR-...-AH-...

35

Setup

LED indicators

LED

Color

State

Significance

STATE

green

illumi-

nated

Normal operation

flashing

Teach-in operation or Power Up 

(further signal functions: see status table)

DIA

red

illumi-

nated

- Internal electronics fault

- Fault at the inputs/outputs

LED 1

red

freely configurable*

LED 2

green

freely configurable*

*)

 Can vary depending on version. See data sheet.

Teach-in function for actuator

The actuator must be allocated to the safety switch using a teach-in function before 

the system forms a functional unit.
During a teach-in operation, the safety outputs and the monitoring output OUT are 

in a high-resistance state, i.e. the system is in the safe state.
Depending on the version, the teach-in operation is automatic or is undertaken 

with the aid of the teach-in input J. 

TIP: We recommend performing the teach-in operation prior to mounting. Mark 

switches and actuators that belong together in order to avoid confusion. For de-

vices to be connected in series, we recommend performing the teach-in operation 

separately for each device prior to series connection.

Important:

 Ì

The teach-in operation may be performed only if the device functions flaw-
lessly. The red LED DIA must not be illuminated.

 Ì

The safety switch disables the code of the previous actuator if teach-in is 
carried out for a new actuator. Teach-in is not possible again immediately for 
this actuator if a new teach-in operation is carried out. The disabled code is 
released again in the safety switch only after a third code has been taught.

 Ì

The safety switch can only be operated with the last actuator taught.

 Ì

Version without teach-in input: If the switch detects the actuator that was 
most recently taught when in teach-in standby state, this state is ended im-
mediately and the switch changes to normal state. 

 Ì

Versions with teach-in input: Teach-in operation ends when the power supply 
to the teach-in input is interrupted, but no later than after 3 min. If no actua-
tor was detected during this time, the device enters the fault state.

 Ì

The actuator being taught is not activated if it is within the operating dis-
tance for less than 60 s.

LED2

STATE (gn)