Operating Instructions Safety Switch CET.-AR-...-AH-...

14

Using mechanical release
1.  Unscrew locking screw 
2.  Operate the mechanical release through the threaded bore of the locking 

screw (e.g. with a metal rod ∅ 3 mm) 

¨

The safety device can be opened

The locking screw must be screwed back in and sealed after use (for example 

with sealing lacquer).
The monitoring output OUT is switched off; OUT D can assume an undefined state.  

Open the safety door and close it again after resetting the mechanical release. 

The device will then operate normally again.

Changing the approach direction

1.  Remove the screws from the safety switch
2.  Set the required direction
3.  Tighten the screws with a torque of 1.5 Nm.

Fig. 1: Changing the approach direction