Edgevac, Kinze sensor configuration, Muxbus sensor detection – Kinze Ag Leader Integra User Manual

Page 221: Kinze sensor configuration muxbus sensor detection, Information, see, Kinze p

Advertising
background image

205

P

LANTING

KINZE P

LANTER

M

ONITOR

M

ODULE

• EdgeVac Sensors

Use

/

to enter the number of EdgeVac® sensors on the planter. Calibrate EdgeVac sensors

once a year. To start process, press the Calibrate button.

• Tank Pressure
Check the box only if the planter is equipped with tank pressure sensor. Calibrate the sensor once a year.
To start process, press Calibrate button.

EdgeVac

Use /

to enter the number of EdgeVac® sensors.

Calibrate EdgeVac sensors once a year. To start process, press Calibrate button. For more information,
see

“KINZE EdgeVac Calibration” on page

209

.

KINZE Sensor Configuration

Press: Home button > Setup (wrench) button > Configuration (tractor) button > Configuration tab > your
specific configuration > Setup (wrench) button > Seed Monitor button > Sensor Configuration button

The Sensor Configuration screen is for system
maintenance of the KINZE Population Monitor.

• The Install button installs a row sensor.

• Remove button
Removes the highlighted sensor of any type.

• Revive button

Allows the display to reattempt communication with the

highlighted sensor of any type.

• Ignore button
Tells the display to cease communications with a row
sensor.

• View button

Shows the Sensor Information screen. For more information, see

“Sensor Information” on page

207

.

Note: After initial configuration of the KINZE Planter Monitor, complete the Sensor Muxbus Detection process.
For more information, see

“Muxbus Sensor Detection” on page

205

.

Muxbus Sensor Detection

After initial configuration of the KINZE Planter Monitor, complete the Sensor Muxbus Detection process.
This process allows the muxbus to detect each sensor on the planter. In order for the display to show the
correct Planter Monitor information, complete the detection process for each muxbus sensor.

Note: Be sure that all sensors are unplugged before beginning the process. If any sensors are plugged in,
the Muxbus Detection process will abort. If this occurs, unplug all sensors and retry procedure.

Configuration

Select Your Specific

Configuration

Seed Monitor

Sensor Configuration

Rear Section

Row 1 OK

Row 2 OK

Row 3 OK

Row 4 OK

Row 5 OK

Row 6 OK

Row 7 OK

Install

Remove

Revive

Ignore

View

Item Status

Sensor Configuration

Row 8 OK

Row 9 OK

Row 10 OK

Advertising