Kinze Ag Leader Integra User Manual

Page 255

Advertising
background image

239

A

PPLICATION

L

IQUID

R

ATE

C

ONTROL

Dickey-john NH3 Heat
Exchanger

In-line Servo

40%

10%

8

Flow Control Valve

or Sprayer Model

(and year if

applicable)

Control System

PWM Frequency

Typical Gain Range

Zero Offset

Allowable Error

Valve Response

1

Valve Response

2

Response Threshold

Apache 510/710/
1010/1210 (2006
and up)

In-line Servo

2%

100%

24%

Use a starting value of 5.

See note below.

All Case IH
sprayers when
using AIM
Command

AIM Command In-
line servo

2%

100%

24%

3

Case IH Surveyor
with A-post

Non-AIM
Command Mode
PWM
12-volt

122

**700-

900

35

2%

Case IH 3320

Non-AIM
Command Mode
PWM
12-volt

122

**700-

900

35

2%

Case IH 4420 with
A-post

Non-AIM
Command Mode
PWM
12-volt

122

**700-

900

35

2%

Case IH 3200
(KZKCO Valve)

Non-AIM
Command Mode
By-Pass Servo

2%

40%

10%

5

Case IH 4260 with
Raven valve

Non-AIM
Command Mode
By-Pass Servo

2%

100%

24%

3

Flow Control Valve

Control Valve

Configuration

Valve Response

1

Valve Response

2

Response

Threshold

Advertising