Flow monitor warning, Calibrating an injection pump, Performed. for more information, see – Kinze Ag Leader Integra User Manual

Page 266: Calibrating an

Advertising
background image

250

Firmware Version 5.2

• Error Delay
The number of seconds that the actual rate falls out of the error threshold before an alarm sounds.

Flow Monitor Warning

• Error Threshold
The percentage of perceived application error, based on the discharge flow sensor.

• Enable Warning
The Enable Warning check box allows you the option of displaying the Flow Monitor Warning.

Calibrating an Injection Pump

Calibrate the injection pump at the beginning of each season and any time repairs are made.

Press: Home button > Setup (wrench) button > Configuration (tractor) button > Configuration tab > your
specific configuration > Setup (wrench) button > 2 tab >Controller Settings button

1. Enter Factory Calibration

Before entering a Direct Injection Calibration, a Factory Calibration must be entered. If you have not already
done so, enter the Factory Calibration Number by pressing the Factory Calibration button. This number is
found on the tag of the Digital Pump Speed Sensor. This tag number represents pulses per 10 fluid ounces.
Divide the tag number by 10 and enter this number. Once entered, this number should not be changed.

2. Press Perform Calibration

Underneath Pump Calibration, press the Perform Calibration button.

3. Prime the Direct Injection Pump

The Pump Calibration Wizard appears. Before beginning this calibration procedure, it is recommended that
you first prime the Direct Injection pump. Press the Prime button and continue along with the priming
procedure as described in

“Priming an Injection Pump”

, beginning with Step 3 on

page

251

. After the priming

procedure is finished, you will return to this Pump Calibration Wizard window. Press

to continue.

4. Enter the Dispense Amount

Enter the amount that you want dispensed. Press

to continue.

5. Acknowledge the Warning

Prepare to catch any product dispensed in an appropriate container. Press

to continue.

6. Start Calibration

Press the green-colored START button to begin the calibration procedure. The Pump Calibration Wizard
automatically counts up to the amount that you specified in Step 4. The button will turn red and displays
STOP while the product is being dispensed. When the procedure is finished, the button will again turn

green. Press

to continue.

Note: You may press the Reset button if you wish to start the calibration procedure over.

Configuration

Select Your Specific

Configuration

Controller Settings