Control valve settings - pwm, Control, Pplication – Kinze Ag Leader Integra User Manual

Page 239: Iquid, Ontrol

Advertising
background image

223

A

PPLICATION

L

IQUID

R

ATE

C

ONTROL

Control Valve Settings - PWM

• PWM Frequency
The frequency that the PWM control valve is
pulsed at. Settings can be found from the
manufacturer of the valve. Typical settings
range from 100-125 Hz.

Note: See PWM valve manufacturer information for recommended settings.

• PWM Gain
Determines how aggressively the control valve responds when making rate change adjustments. The
higher the value the more aggressive the system response is.

• Zero Flow Offset
Represents the maximum duty cycle that is sent to the control valve without producing any hydraulic flow
from the PWM valve. Using too high of a Zero Flow Offset value can cause the product control system to
not properly control low rates. See the PWM valve manufacturer information for recommended settings.

• PWM Standby
This is a user-defined setting that determines the percent duty cycle the system uses when the booms are
all off. The setting must be greater than the Zero Flow Offset.

Note: The current PWM Duty Cycle can be viewed at the Liquid Diagnostics screen. For more information,
see

“Liquid Application Diagnostics” on page

233

Control Valve Settings - Servo, Calibrated Reflow and Ramsey Valve

• Valve Response 1
Determines the speed of the servo valve when
product control error exceeds the Response
Threshold setting. The default for this setting is
100%. Decreasing the value will cause the servo
valve to run slower. Valve Response 1
represents the fast speed of the servo valve.

• Valve Response 2
Determines the speed of the servo valve when
product control error is less than the Response
Threshold setting. The default for this setting is
24%. Decreasing the value will cause the servo
valve to run slower. Valve Response 2
represents the slow speed of the servo valve.

Control Valve Settings

PWM 12 volt

Control Valve:

PWM Frequency

PWM Gain

Zero Flow Offset

PWM Standby

50

30

800

100

Allowable

Error

2 %

3 gal/min

Control Valve Settings

Control Valve:

Inline Servo

Valve

Response 1

Valve

Response 2

Response Threshold

100

24

Allowable

Error

2 %