6 programming languages, 1 structured text - st, 2 awl / il – Lenze PLC Designer Migration PLC Designer (R2-x)-PLC Designer (R3-x) User Manual

Page 16: 3 fup / fbd, 4 kop / ld, 1 function blocks, 2 blocks with en/eno, Programming languages, Structured text - st, Awl / il

Advertising
background image

Programming languages

Structured text - ST

16

Lenze · PLC Designer | Migration of V2.x projects · 1.2 EN - 02/2013

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6

Programming languages

This chapter describes the restrictions of the single programming languages when a »PLC Desig-

ner«-V2 project is imported into the »PLC Designer« V3.

6.1

Structured text - ST

No restriction known

6.2

AWL / IL

No restriction known

6.3

FUP / FBD

No restriction known

6.4

KOP / LD

6.4.1

Function blocks

Function blocks may only be used in parallel branches that are directly connected to the power rail.

• Example: Network 1 cannot be imported, network 2 (same function as network 1) can be impor-

ted.

6.4.2

Blocks with EN/ENO

Blocks with EN/ENO must not be provided with any further blocks at the inputs. A variable is per-

mitted.

Advertising