Update of a project from V2.x to V3.x

Import of the example project into the »PLC Designer« V3.x

22

Lenze · PLC Designer | Migration of V2.x projects · 1.2 EN - 02/2013

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Select the matching library from this folder.

• In this case, replace: SysLibCallback.lib (V2) by SysCallback23.lib (V3).

The library replacements already saved on the system can be checked and edited via

ToolsOptionsLibraries:

The installation of the »PLC Designer« V3 contains a reference list with predefined standard

replacements. The libraries contained in this list are replaced automatically. When a device is added

(Controller or fieldbus) to the control configuration, the required libraries are loaded automatically.