5 speed limit value conditioning, Speed limit value conditioning (c 16), 9400 technology applications | actuator – torque – Lenze E94AxHE Technology Application Actuating drive - Torque User Manual

Page 16

Advertising
background image

9400 Technology applications | Actuator – torque

Parameter setting & configuration

Speed limit value conditioning

16

L

EDS94TA10020xxxx EN 1.1 - 10/2008

4.5

Speed limit value conditioning

[4-5]

Speed limit value conditioning (schematic diagram)

The speed limit value is defined in the Lenze setting via the analog input 2.

r

The defined speed limit value refers to the direction of rotation which can be set freely

with positive torque.

r

The speed limit value in negative direction of rotation equals, according to amount, the

limit value for the positive direction of rotation.

r

If the speed of the drive is inside the limitations, the motor generates the specified

torque.

r

If the positive or negative speed limit value (for CW or CCW rotation) is reached, the

drive changes to the speed-controlled operation. The set speed limit values are not

exceeded.

r

If the specified speed limit value directly corresponds to the line speed, the internal

limit value can be increased by entering an offset in C03008.

r

Parameter setting: Application parameters tab  dialog level Overview

Offset

Selection

LS_Torque...

M

Torque
setpoint

DI2

DI4

OUT

IN

Ramp generator

%

1

%

2

%

15

Fixed setpoints

Status

machine

(basic drive

functions)

Speed limit

AIN2

M

v

F

Parameter

Lenze setting

Value Unit

C03008

Offset for limit speed

0.00 %

Setpoint inputs of the function

Signal configuration

Lenze setting

Setpoint input

(Multiplexer parameters)

AIN 2  Upper limit speed

C03006

Inverse upper limit

speed



Lower speed limit value

C03171