11 signal configuration, 1 drive and motor interface, 9400 technology applications | actuator – torque – Lenze E94AxHE Technology Application Actuating drive - Torque User Manual

Page 26

Advertising
background image

9400 Technology applications | Actuator – torque

Parameter setting & configuration

Signal configuration

26

L

EDS94TA10020xxxx EN 1.1 - 10/2008

4.11

Signal configuration

4.11.1

Drive and motor interface

If required, the preset signal configuration of the control and setpoint inputs of the drive

and motor interface can be easily reconfigured per parameter setting of the assigned

multiplexer parameters.

Drive interface

Motor interface

Signal (Lenze setting)

Control input

Signal configuration

FALSE  Set controller inhibit

C03130/1

FALSE  Set error

C03130/2

Axis control word bit 00  Switch on drive

C03130/3

DIGIN 5  Reset error 1

C03130/4

Axis control word bit 07  Reset error 2

C03130/5

FALSE  Reset error 3

C03130/6

Signal (Lenze setting)

Setpoint input

Signal configuration

100 %  Upper torque limit value

C03141/1

-100 %  Lower torque limit value

C03141/2

100 %  Adaptation of mass inertia

C03141/3