12 application error messages, 9400 technology applications | actuator – torque – Lenze E94AxHE Technology Application Actuating drive - Torque User Manual

Page 29

Advertising
background image

EDS94TA10020xxxx EN 1.1 - 10/2008

L

29

9400 Technology applications | Actuator – torque

Parameter setting & configuration

Application error messages

4.12

Application error messages

For the output of application-specific error messages an FB instance L_DevApplErr1 of the

function block L_DevApplErr is available.

r

Via the 8 boolean inputs up to 8 different application error messages with

parameterisable module ID, error ID and error response can be activated by the

application.

r

Parameter setting: All parameters tab

Reset of error message
In the Lenze setting the digital input DI5 for resetting (acknowledging) an error message is

connected to the input DI_bResetError1 of the drive interface.

Error message

Error ID

Error response

1

Torque follower in limitation

8001

Warning locked

2

-

8000

Error

3

-

8000

Error

4

-

8000

Error

5

-

8000

Error

6

-

8000

Error

7

-

8000

Error

8

-

8000

Error

Parameter

Lenze setting

C05900

Module ID

980

C05901/1...8

Error ID 1 ... 8

See table above

C05902/1...8

Error response 1 ... 8

See table above

Advertising