3 torqueramp, 9400 technology applications | actuator – torque – Lenze E94AxHE Technology Application Actuating drive - Torque User Manual

Page 32

Advertising
background image

9400 Technology applications | Actuator – torque

Parameter setting & configuration

Parameterisable function blocks

32

L

EDS94TA10020xxxx EN 1.1 - 10/2008

4.13.3

TorqueRamp

C03539/2

Hold setpoint output

• Display of input signal

bHoldOutput.

0 Setpoint output enabled
1 Hold setpoint output

C03539/3

Activate stop

• Display of input signal bStop.

0 Stop not active
1 Stop requested

C03539/4...7

Activate fixed setpoint 1 ... 8

• Display of input signals bJog1 ...

bJog8.

0 Jog input not active
1 Jog input active

C03539/8...11

Activate ramp parameter 1 ... 8

• Display of input signals bTi1 ...

bTi8.

0 Ti input not active
1 Ti input active

C03539/12

Load external setpoint

• Display of input signal

bLoadExtSpeedSetpoint.

0 Loading not active
1 Load external setpoint

C03539/13

Load motor speed

• Display of input signal

bLoadActualMotorSpeed.

0 Loading not active
1 Load motor speed

Parameter

Possible settings

Information

Is an instance of

Function

L_SdRampGenerator

Ramp generator for torque setpoint



Ramp generator (C 15)

Parameter

Possible settings

Information

C03550

0.001

s

1000.000 Acceleration / deceleration time

• Initialisation: 0.010 s

C03551

0.001

s

10.000 S-ramp time

• Initialisation: 0.001 s

C03552

-200.000

%

200.000 Setpoint at the input

• Display of input signal dnIn_n.

C03553

-200.000

%

200.000 Setpoint at the output

• Display of output signal dnOut_n.

Advertising