13 parameterisable function blocks, 1 l_devapplerr1, 2 speedramp – Lenze E94AxHE Technology Application Actuating drive - Torque User Manual

Page 30: 9400 technology applications | actuator – torque

Advertising
background image

9400 Technology applications | Actuator – torque

Parameter setting & configuration

Parameterisable function blocks

30

L

EDS94TA10020xxxx EN 1.1 - 10/2008

4.13

Parameterisable function blocks

This subchapter lists all relevant parameterisable function blocks of the technology

application and the corresponding parameters in alphabetical order.

4.13.1

L_DevApplErr1

4.13.2

SpeedRamp

Is an instance of

Function

L_DevApplErr

Error handling



Application error messages (C 29)

Parameter

Possible settings

Information

C03900

980

999 Module ID

C03901/1...8

0

65535 Error ID

C03902/1...8

Error response

0 None
1 Fault
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information

Is an instance of

Function

L_SdSpeedSet

Ramp generator for speed limit value



Speed limit value conditioning (C 16)

Parameter

Possible settings

Information

C03500/1...15

-200.00

%

200.00 Fixed setpoint 1...15

C03501

0

15 Active setpoint

• Read only

C03502

0.000

s

1000.000 Basic acceleration time

• Initialisation: 1.000 s

C03503

0.000

s

1000.000 Basic deceleration time

• Initialisation: 1.000 s

C03504

0.000

s

10.000 Basic S-ramp time

• Initialisation: 0.100 s

C03507

Polarity of bStop input

0 Active HIGH
1 Active LOW

C03508

0.00

%

100.00 Setpoint tolerance reached

• Initialisation: 1.00 %

Advertising