TROUBLESHOOTING

A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems

encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department.

Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel.

All electronic components have 120 volt ac and/or low voltage dc potential on their terminals. Shorting of
terminals or the application of external voltages may result in board failure.

Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent. If an
intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a
terminal or crimp.

Keep away from combustibles.

WARNING – • Exercise extreme caution when servicing electrical equipment.

• Unplug the dispenser when servicing, except when electrical tests are specified.
• Follow recommended service procedures
• Replace all protective shields or safety notices

PROBLEM

Doesn't work
(Switches do nothing, auger not
turning, no hopper lid lights, no fan,
no compressor sound.)

Hopper Lid Lights not on

PROBABLE CAUSE

1. No power or incorrect voltage to
the dispenser

2. ON/OFF Switch

1. DAY/NIGHT Switch

2. Lamp Cord Assembly

REMEDY

(A) Check for proper voltage at the
wall outlet.

(B) Check circuit breakers or fuses.

(A) The ON/OFF Switch must be in
the "ON" position.

(B) Refer to

Service

- Dispenser ON/

OFF Switch for testing procedures.
See page 37.

(A) The DAY/NIGHT Switch must be
in the "DAY" position.

(B) Refer to

Service

- DAY/NIGHT

Switch for testing procedures. See
page 36.

(A) The lamp cord must be plugged
into the lamp cord connector.

(B) Refer to

Service

- Lamp Cord

Assembly for testing procedures. See
page 42.

27646 122200