Bunn CDS-3 User Manual

Page 44

Advertising
background image

44

Removal and Replacement:
1. Disconnect the lamp cord assembly from the lamp

cord connector assembly in the top of the auger
motor cover.

2. Remove the hopper cover with the lamp cord

assembly from the hopper.

3. Remove hopper cover liner from the hopper cover.
4. Cut off the closed-end splices connecting lamp cord

assembly to the lamp holder/socket assembly.

5. Remove the two lamps.
6. Remove the two #2-56 screws and elastic lock

nuts securing the lamp holder/socket assembly to
the mounting bracket. Remove lamp holder/socket
assembly and discard.

7. Install new lamp holder/socket assembly on mount-

ing bracket using two #2-56 screws and elastic
lock nuts.

8. Reinstall lamps.
9. Strip the wires from the lamp cord assembly

approximately .375”.

10. Using the two wire nuts, supplied, connect the

lamp cord assembly to the new lamp holder/
socket assembly wires.

11. Reinstall the hopper liner to the bottom of the

hopper cover.

12. Reinstall the hopper cover to the hopper.
13. Plug in the lamp cord assembly to the lamp cord

connector assembly on left top of the auger motor
cover.

14. Refer to Fig. 42 when reconnecting the wires.

FIG. 42 LAMP HOLDER/SOCKET ASSEMBLY

WIRES

P1322

SERVICE (cont.)

LAMP HOLDER/SOCKET ASSEMBLY

FIG. 41 LAMP HOLDER/SOCKET ASSEMBLY

P1343

Location:

The lamp holder/socket assemblies are located

inside the hopper covers.

Test Procedures:
1. Disconnect the lamp cord assembly from the lamp

cord connector.

2. Remove the lamps from the lamp holder/socket

assembly.

3. With a voltmeter, check the voltage across the pin

sockets in the plugs with the DAY/NIGHT switch in
the “-” down position and ON/OFF switch in the
“ON” position. Reconnect the lamp cord to the
lamp cord connector. The indication must be
approximately 12.6 volts dc.

4. Disconnect the lamp cord from the lamp cord

connector.

If voltage is present as described, the lamp holder/
socket assembly is operating properly.
If voltage is not present as described, replace the lamp
holder/socket assembly.
5. Check for continuity across the terminals on the

lamps.

If continuity is present as described, the lamps are
operating properly.

If continuity is not present as described, replace the
lamp.

27646 122200

Advertising
This manual is related to the following products: