Bunn CDS-3 User Manual

Page 33

Advertising
background image

33

SERVICE (cont.)

COMPRESSOR & COMPONENTS (CDS-3) (cont.)

Compressor Thermal Overload Protector: Refer to FIG.
17
1. Remove terminal cover retainer (7) and terminal

cover (6).

2. Remove the wire from thermal overload protector

from the compressor wiring harness to the thermal
overload protector.

3. Remove overload protector retainer (5) and ther-

mal overload protector (4) as an assembly

4. Remove retainer (5) from overload protector (4)

and discard overload protector.

5. Install retainer (5) on new overload protector (2).
6. Install retainer (5) and overload protector (4) on

the compressor terminal bracket.

7. Refer to Fig. 20 and reconnect the thermal over-

load protector wires.

8. Reinstall terminal cover (6) and cover retainer (7).

FIG. 20 THERMAL OVERLOAD PROTECTOR

TERMINALS

Compressor Start Relay

WARNING: The compressor start capacitor must be
properly discharged before proceeding.
1. Disconnect the wires from the compressor relay.
2. Remove the #6-32 screw securing the relay to the

rear of the component bracket.

3. Remove and discard relay.
4. Install new relay on the rear of the component

bracket and secure with a #6-32 screw.

5. Refer to Fig. 19 and reconnect the wires.

FIG. 19 COMPRESSOR RELAY TERMINALS

T4 WHI from Compressor
and Main Harness
T4 BLK from Run Capacitor

T5 BLK from Compressor
Thermal Overload Protector
and Main Harness
T1 BLK from Start Capacitor
T2 BLK from Run Capacitor
T2 Red from Compressor

P1820

BLK to Compressor Relay T5

P1821

START

RUN

BLK to Compressor
Relay T1

BLK to Compressor
Relay T6

BLK

BLK to Compressor
Relay T2

P1817

FIG. 18 COMPRESSOR CAPACITOR TERMINALS

Compressor Start Capacitor:

WARNING: The compressor start capacitor must be
properly discharged before proceeding.
1. Disconnect the two leads on the compressor start

capacitor.

2. Loosen the capacitor retaining strap and remove

the capacitor.

3. Securely install new start capacitor under the

retaining strap.

4. Refer to Fig. 18 and reconnect the wires to the start

capacitor.

Compressor Run Capacitor:

WARNING: The compressor run capacitor must be
properly discharged before proceeding.
1. Disconnect the three leads from the compressor

run capacitor.

2. Loosen the capacitor retaining strap and remove

the capacitor.

4. Securely install new run capacitor under the re-

taining strap.

5. Refer to Fig. 18 and reconnect the wires to the relay.

27646 122200

Advertising
This manual is related to the following products: